ADA signage code · 12 min read

ADA sign requirements: braille, raised text, spacing and mounting height

By Sign Planner · Published November 20, 2026 · Updated November 21, 2026

If you make, specify or install signs, the ADA rules for tactile signs come down to a short list of numbers: how tall the raised letters are, how big the braille dots are, how far apart everything sits, and how high and where the sign goes on the wall. This guide puts them in one place. Every rule links to the official text so you can check it yourself.

The numbers here are from the federal 2010 ADA Standards for Accessible Design, Section 703 (Signs). Your state or city may add stricter rules, so confirm with your local authority before you build. This is a plain-English summary, not legal advice.

Which signs need raised text and braille

Signs that name a permanent room or space must have raised characters and braille. That means room numbers, restrooms, room names, and floor numbers or letters. The rule is in ADA §216.2 Designations, which points to the tactile requirements in §703.2.

Where a restroom or similar pictogram labels a permanent space, it also needs a raised and braille text descriptor next to it, and the pictogram sits in a field at least 6 inches tall (§703.6.1). Directional and informational signs, such as arrows pointing to the lobby, only need to meet the visual character rules in §703.5 (§216.3).

You can build one sign that carries both visual and tactile text, or two separate signs, one visual and one tactile (§703.1).

Raised character requirements

Raised characters are the letters and numbers you read by touch. All of the rules below are in ADA §703.2, and the Access Board's illustrated guide to signs shows each one. Click a rule, or a part of the drawing, to see the two together.

RequirementWhat the code says
Raised depth§703.2.1At least 1/32″ (0.8 mm) above the background.
Case§703.2.2Uppercase only.
Font style§703.2.3Sans serif. Not italic, oblique, script, highly decorative, or other unusual forms.
Proportions§703.2.4The width of the uppercase “O” must be 55% to 110% of the height of the uppercase “I”.
Character height§703.2.55/8″ (16 mm) minimum, 2″ (51 mm) maximum, measured vertically from the baseline and based on the uppercase “I”. If a separate visual copy of the same information is also provided, the raised height can drop to 1/2″ (13 mm) minimum.
Stroke thickness§703.2.6The stroke of the uppercase “I” can be no more than 15% of the character height.
OFFICE2045/8″ – 2″char height135 – 170%of height,baseline tobaseline3/8″ min3/8″3/8″ minIllustrative layout · braille dots enlargedLetter shapes (not to scale)≤ 15%1/8″O width55–110% of I5/8″–2″letter “I”UPPERCASESans serifSide view (exaggerated)Raised letters≥ 1/32″ tallflat-toppedBraille dotsdomed, own rule0.025–0.037″ tall
Click a rule in the table, or a highlighted part of the drawing.

Braille requirements

Raised characters must be duplicated in braille (§703.2). Braille must be contracted (Grade 2) and follow the dimensions in §703.3.

RequirementWhat the code says
Grade§703.3Contracted (Grade 2) braille.
Dot shape§703.3.1Domed or rounded.
Dot base diameterTable 703.3.10.059″ to 0.063″ (1.5 to 1.6 mm).
Dot heightTable 703.3.10.025″ to 0.037″ (0.6 to 0.9 mm).
Dot to dot, same cellTable 703.3.10.090″ to 0.100″ (2.3 to 2.5 mm), center to center.
Cell to cell, same rowTable 703.3.10.241″ to 0.300″ (6.1 to 7.6 mm) between corresponding dots in adjacent cells, center to center.
Row to rowTable 703.3.10.395″ to 0.400″ (10 to 10.2 mm) between corresponding dots in the cell directly below, center to center.
Capital letters§703.3.1Use the capital indicator only before the first word of a sentence, proper nouns and names, individual letters, initials, and acronyms.

Dot size and spacing depend on the braille font and its point size, which is why braille font vendors publish the size to use (often 24 pt) so the dots land inside Table 703.3.1.

Braille cells, shown to scalebase 0.059–0.063″0.090–0.100″dot to dot, in cell0.241–0.300″cell to cell0.395–0.400″line to lineDot side view (3× enlarged)domed or rounded0.025–0.037″Grade 2 (contracted)Capital indicator: limited use
Click a rule in the table, or a highlighted part of the drawing.

Spacing: characters, lines, braille and borders

These are the rules people most often get wrong, because they are measured between specific points. Here they are in one table, with braille position first.

RequirementWhat the code says
Braille position§703.3.2Below the matching text. If the text has several lines, braille goes below all of them.
Between raised characters§703.2.7Measured between the two closest points of neighboring characters, ignoring word spaces. For characters with a rectangular cross section: 1/8″ (3.2 mm) minimum and no more than 4 times the stroke width. For other cross sections: 1/16″ (1.6 mm) minimum at the base and 1/8″ (3.2 mm) minimum at the top, and no more than 4 times the stroke width at either.
Between lines of raised text§703.2.8Baseline to baseline: 135% minimum and 170% maximum of the raised character height.
Braille to raised text§703.3.2At least 3/8″ (9.5 mm) between braille and any other tactile characters.
Braille to raised borders§703.3.2At least 3/8″ (9.5 mm) from raised borders and decorative elements.
Raised characters to raised borders§703.2.7At least 3/8″ (9.5 mm) from raised borders and decorative elements.
OFFICE2045/8″ – 2″char height135 – 170%of height,baseline tobaseline3/8″ min3/8″3/8″ minIllustrative layout · braille dots enlargedLetter shapes (not to scale)≤ 15%1/8″O width55–110% of I5/8″–2″letter “I”UPPERCASESans serifSide view (exaggerated)Raised letters≥ 1/32″ tallflat-toppedBraille dotsdomed, own rule0.025–0.037″ tall
Click a rule in the table, or a highlighted part of the drawing.

What about the space between the text and the edge of the plaque?

The ADA does not set a minimum margin between raised characters and the outer edge of the sign. The only edge-related rule is the 3/8″ clearance from raised borders and decorative elements above. A plain sign with no raised border has no federal edge requirement.

Most shops still keep a comfortable margin so letters aren't crowded to the edge, but that is a fabrication habit, not code. Check whether your state or local code sets its own number.

Mounting height: where to measure from

Tactile characters must sit between 48″ and 60″ above the finished floor, and the rule says exactly where each measurement is taken (ADA §703.4.1). The Access Board's guide shows this with the 48″ dimension drawn to the braille baseline and the 60″ dimension drawn to the text baseline (Chapter 7: Signs, Installation Height and Location). The only exception in §703.4.1 is elevator car controls. Try it: drag the sign in the drawing. It turns green when it is in code and red when it is not, and the dimensions update as you move it.

RequirementWhat the code says
Lowest point: 48″ minimum§703.4.1The baseline of the lowest tactile character must be at least 48″ (1220 mm) above the finished floor or ground. On a sign with braille under the text, that is the baseline of the braille.
Highest point: 60″ maximum§703.4.1The baseline of the highest tactile character must be no more than 60″ (1525 mm) above the finished floor or ground. That is the baseline of the top line of raised text.

Quick check: the whole tactile block, from the bottom of the braille to the baseline of the top line of text, has to fit inside the 48″ to 60″ window. A tall sign with many lines can run out of room, which is when you need to shorten the copy or resize the sign.

Drag the sign · wall elevationFINISH FLOORDOOR 3'-0"60″ max · top line baseline48″ min · braille baseline52.6″top line baseline50.8″braille baseline11.5″ latch edge to sign centerno fixed gap in the ADAheights are measured from the finished floor, to the baselines
✓ In codeBraille baseline 50.8″ (min 48″) · top baseline 52.6″ (max 60″) · alongside the door on the latch side, 11.5″ from the latch edge to the sign’s center.
Click a rule in the table, or a highlighted part of the drawing.

Mounting location: where the sign goes at a door

Placement is covered by ADA §703.4.2. The dark bar in each drawing is the sign.

RequirementWhat the code says
Single door§703.4.2Alongside the door, on the latch side.
Double doors, one active leaf§703.4.2On the inactive leaf.
Double doors, both leaves active§703.4.2To the right of the right-hand door.
No wall space at the latch§703.4.2If there is no wall space on the latch side of a single door, or on the right side of double doors, the sign goes on the nearest adjacent wall.
Clear floor space§703.4.2An 18″ by 18″ minimum area, centered on the tactile characters, must be clear beyond the arc of the door swing between the closed position and 45 degrees open. This keeps someone reading the sign from being hit by the door.
Push-side exception§703.4.2A tactile sign is allowed on the push side of a door that has a closer and no hold-open device.
Single doordoor swingclosed → 45°18″ × 18″ clearsign, latch sidePush side with a closer: also allowedDouble doors, one active leafinactive leafactive leafDouble doors, both activeright of theright-hand doorNo wall space at the latchsign on thenearestadjacentwall
Click a rule in the table, or a highlighted part of the drawing.

Notice what the federal rule does not give: a fixed distance from the door frame to the edge of the sign. The location is defined by the latch side and the 18″ by 18″ clear floor space, so the right gap depends on the door swing and the wall. Confirm any additional distance your local code requires.

Restroom door symbols: triangle, circle and unisex (California)

This is a California rule, not a federal ADA rule. The 2010 ADA Standards list the symbols a sign may need (accessibility, TTY, volume control and assistive listening in §703.7.2) and none of them is a geometric restroom symbol. California's building code (CBC Chapter 11B) adds one: a raised geometric shape on the door to every men's, women's and unisex toilet and bathing room. Outside California, check whether your state or local code adopts it.

California's guide notes that you do not need a gender pictogram alongside the shape. Where a room has an opening instead of a door, the shape can be the background of the tactile sign, with raised characters and braille on it (Advisory 11B-703.7.2.6).

RequirementWhat the code says
Men’s: triangleCBC §11B-703.7.2.6.1An equilateral triangle, 1/4″ (6.4 mm) thick, with edges 12″ (305 mm) long and a vertex pointing up.
Women’s: circleCBC §11B-703.7.2.6.2A circle, 1/4″ (6.4 mm) thick and 12″ (305 mm) in diameter.
Unisex: circle with triangleCBC §11B-703.7.2.6.3A 12″ circle, 1/4″ thick, with a 1/4″ thick triangle (vertex up) superimposed on it and inscribed within the circle. The triangle’s vertices sit no more than 1/4″ (6.4 mm) from the circle’s edge.
ContrastCBC §11B-703.7.2.6.1–.3The men’s triangle and the women’s circle must contrast with the door, light on dark or dark on light. On the unisex symbol, the triangle must contrast with the circle, and the circle with the door.
Edges and verticesCBC §11B-703.7.2.6.4Edges eased or rounded at 1/16″ (1.59 mm) minimum, or chamfered at 1/8″ (3.2 mm) maximum. Vertices radiused between 1/8″ (3.2 mm) and 1/4″ (6.4 mm).
MountingCBC §11B-703.7.2.658″ (1473 mm) minimum and 60″ (1524 mm) maximum above the finished floor, measured from the centerline of the symbol. Where there is a door, the symbol is mounted within 1″ (25 mm) of the door’s vertical centerline.
California door symbols, shown to scale12″ edges12″ diametertips ≤ 1/4″ from the edge12″ diameterMen’sWomen’sUnisexContrast: light on dark or dark on lightEased edges · radiused tips58″ min – 60″ maxto the symbol’scenterlineand within 1″ of the door’svertical centerline (dashed)
Click a rule in the table, or a highlighted part of the drawing.

How Sign Planner checks this for you

Looking up every one of these numbers for every sign type is slow, and a missed spacing rule means remaking signs. Sign Planner builds the code into the way you lay out signs.

  • Build layouts fast in the Sign Layout Generator. Set up a sign type once, with its panel, text, braille and tags, and every sign of that type lands on the sheet with its message and braille. Switch between the federal ADA ruleset and California's CBC to match your project.
  • It guides you while you build. Raised character height, line spacing, character spacing and the braille gap are locked to the code range as you type. Every check names the rule it is based on, so a flag is never a vague “not compliant”.
  • The elevation sheet shows what is in code and what isn't. Each sign on the sheet is marked red when it fails a code check and amber when it needs a look. Hover to see which rule, then click to open that sign in the builder and fix it. Before you export, Sign Planner lists any sign still failing a check.

Sign Planner checks the sign face: sizes, spacing, braille and contrast. Mounting height and door location are still decided on site, so use the sections above when you set mounting details. Always review layouts and code compliance before sending anything to fabrication. Planning a whole project? See how to create a sign schedule.

Build code-checked sign layouts in minutes

Try Sign Planner free for 3 days. Full access, no credit card required.

Start free trial

Sources

This article summarizes the 2010 ADA Standards for Accessible Design and is for general information, not legal advice. State and local codes can be stricter. Always confirm requirements for your project with the authority that has jurisdiction.